Important
The SingleStore 9.1 release candidate (RC) gives you the opportunity to preview, evaluate, and provide feedback on new and upcoming features prior to their general availability. In the interim, SingleStore 9.0 is recommended for production workloads, which can later be upgraded to SingleStore 9.1.
Connect with Tibco Spotfire
On this page
Tibco Spotfire is a complete analytics solution.
The following certification matrix shows the recommended Spotfire version and the SingleStore driver:
|
Spotfire Analytics 12. |
SingleStore ODBC Driver |
Prerequisites
-
Download and install Tibco Spotfire (for Windows).
Create an account and register with a username and password. -
Download and install the latest version of The SingleStore ODBC Driver.
Connect Tibco Spotfire to SingleStore
-
Open the Tibco Spotfire desktop application.
A sign in screen is displayed. Select Tibco Login. -
On the web authentication page, log in with the credentials used while registering to download Tibco Spotfire.
-
After logging in, you are redirected to the desktop application and the homepage of Tibco Spotfire is displayed.
-
In Spotfire Analyst, open the Files and data flyout, and select Connect to.
Select SingleStore, and then select New Connection. -
In the connection dialog, enter the following:
-
Server IP address / name
-
Database System ( select SingleStore)
-
Authentication Method as Database Authentication
-
Username to access the database
-
Password to access the database
-
-
Select Connect.
After a successful connection, the Database drop down is populated with all the existing databases. Select a database, and select OK. -
In the connection view window, select the tables you want to import.
-
The Add data to analysis popup is displayed.
Select Add as new data table > Import > OK.
You are now ready to explore your SingleStore data using Tibco Spotfire.
Troubleshooting
-
Issue: Corrupted non-english characters in data loaded through Data Connection.
Resolution: Use the Unicode version of the SingleStore ODBC driver for proper handling of non-english characters in the data.
-
Issue: Fetch performance issue or "Connection reset by peer" error with multiple concurrent connections.
Resolution: Use the latest version of the SingleStore ODBC driver instead of MySQL ODBC drivers.
-
Issue: Data inconsistency due to Prefetch limit of 100000 and Auto-Paging behavior.
Resolution: The default Prefetch limit was removed in Spotfire version 12.
0. 11 LTS, which is the minimum recommended version to use with SingleStore.
Last modified: December 18, 2025